Description
The 8500 Series Concealed Vertical Rod Exit Device is designed for hollow metal applications that require a life-safety exit device with concealed vertical rods for two-point locking.
The 3600 Series Fire-Rated Concealed Vertical Rod Exit Device is designed for hollow metal applications that require a fire-rated exit device with concealed vertical rods for two-point locking.
Designed for use in applications with single doors or pairs of doors.
Model |
Type |
Rating |
Door Construction |
Max Size Single Doors |
Max Size Pairs & Double Egress |
3600 |
CVR |
3 hr |
Hollow metal |
N/A |
8’0″ x 10’0″ |
3600T |
CVR-TRO |
3 hr |
Hollow metal |
N/A |
8’0″ x 10’0″ (std. pairs) |
3600T |
CVR-TRO |
3 hr |
Hollow metal |
N/A |
8’0″ x 8’0″ (double egress) |
3600T |
CVR-TRO |
1-1/2 hr |
Hollow metal |
N/A |
8’0″ x 10’0″ (double egress) |
Certifications:
UL 305 Panic Hardware
3600 only: UL 10(c) fire-rated, up to 3 hours
CAN/ULC S104 fire door conformant
NFPA 252 fire door conformant
Features:
Materials: Push bar made of extruded aluminum, cladded or anodized in a variety of finishes.
Push bar Length: Standard sizes: dimensioned for 30″ [762.0 mm], 36″ [914.4 mm], 42″ [1,066.8mm], and 48″ [1,219.2 mm] openings. Standard width bars can be field cut to the next smallest opening width.
Bar Height: Standard model adjusts from 30″ [762 mm] to 44″ [1117.6 mm].
Handing: Device is non-handed.
Door Thickness: Suits 1-3/4″ [44.5 mm] standard, up to 2-1/4″ [57.2 mm].
Door Height: Standard configuration suitable for doors up to 66″ [1,676.4 mm] above the selected bar height. For doors over 66″ [1,676.4 mm] above bar height, up to 10′ [3.05 m] use 3655 Tall Door Kit available separately.
Stile Width: Minimum 3-1/2″ [88.9 mm]. Door construction may require additional stile width to meet fire ratings and provide adequate strength.
Stile Wall: Doors with stile walls other than 1/8″[3.2 mm] require modification.
Projection: 2-5/8″ [66.7 mm] when fully projected,1-5/8″ [41.3 mm] when dogged.
Dogging: Standard dogging with hex key or with cylinder not available on fire-rated exit devices. Electric dogging option available only.
Fasteners: Standard self-tapping screws and machine screws. Optional Sex Bolt Kits 26-0584 (two required per device) available separately.
Cylinders: Accepts any standard 1″ [25.4 mm] length,1-5/32″ [29.4 mm] diameter mortise cylinder with MS® cam such as the 4036 Mortise Cylinder. Accommodates cylinder lengths from 1″ [25.4 mm] to1-1/4″ [31.8 mm]. Available separately.
Cylinder x Fixed Pull Functions: For entry trim function 03 (Night latch -key releases latch) select any standard1″ [25.4 mm] length, 1-5/32″ [29.4 mm] diameter mortise cylinder with MS® cam such as the 4036 Mortise Cylinder. If key entry operation is required, any standard mortise cylinder with MS® cam can be installed through an 8650 Cylinder Escutcheon. 8650 Cylinder Escutcheon Kit available separately.
Entry Trim Functions: For entry trim function 08 (key locks/unlocks lever) or function 09 (key releases lever) select any standard 1″ [25.4 mm] length, 1-5/32″[29.4 mm] diameter mortise cylinder with MS® cam such as the 4036 Mortise Cylinder. Accommodates cylinder lengths from 1″ [25.4mm] to 1-1/4″ [31.8 mm]. Available separately.
Bolts and Strikes: The patented top latching mechanism utilizes a rotating top bolt which deadlatches around the header strike, interlocking the door to the frame. Supplied with standard header strike. Adjustable protected steel rods. The hexagonal, hardened steel bottom bolt is shielded in a cast housing for strength and stability.
Standard Package: Individually boxed.
Shipping Weight: 12 lbs [5.44 kg]
Options:
• Available in top rod only version, less bottom rod. Specify by adding “T” after exit device model number.
• Electrification Options: (MLR) Motorized Latch Retraction, Electric Latch Retraction(LR), Electric Dogging, Alarm
• Monitoring, Cylinder Dogging, Matching End Caps